Control DT-3 for full spectrum radiators

SKU: DT3
In stock
Versand: kostenfrei für DE | EU | CH | UK
Rückgabe: 30 Tage Rückgaberecht
Geeignet: für Infrarot-Vollspektrum-Strahler
Platzierung: Bedienfeld in der Sauna
€369,00
Tax included Shipping calculated at checkout.
Description

With our innovative "DT-3 control" for infrared full-spectrum heaters, the power can be regulated (intensity dimmed) and Therapiezeit set to.

3-Control Zones dim separately, switch on/off. the Therapy time will always expire for all 3 control zones together.

Thanks to the phase angle control process, there is no loss of valuable short-term infrared «A» components when dimming, which are responsible for deep heat!

Dimensions:
Control panel external dimensions: 88 x 88 x 25 mm
Operating panel installation opening: 75 x 75 mm
Power unit external dimensions: 255 x 160 x 50 mm

Technical specifications:
3 separately adjustable outputs up to 1300 watts each
however, all 3 outputs total max. 3,650 W
Dimming function: 50-60-70-80-90-100%
Time setting: 5-15-30-60-120-180 minutes
3 built-in sockets GST18i3
Safety temperature sensor: 130°C
Connected load: 230V AC, 50/60 Hz

scope of delivery:
1x control panel
1x power section
1x intermediate line 3m
1x aluminum frame of the control panel
1x safety temperature sensor
0x (option) connection cable (control socket)

danger Montage:
The control panel may be mounted at a maximum floor height of 110 cm in the sauna! To be more precise, up to max. 80°C temperature range. Never mount directly in the surrounding area or above the sauna heater (see Zone heater)! The power section must be placed outside the sauna!

Operation of the «DT-3» controller
KEY «I/O» IS BACKLIT:
After connection to the mains voltage, the controller is in stand-by mode.

PRESSING THE «I/O» BUTTON:
LEDs next to the button light up, the control switches on. The values last used for time and power are displayed again, which can be changed accordingly using the arrow keys.

3 ZONES REGULATION:
Tap the desired Zone 1, 2 or 3 button - the button will flash. Use the arrow keys to change the desired power value. The button stops flashing after 5 seconds and the new value is accepted.

TIMELINE:
It can be read from the LEDs above the time display. After the set time has elapsed, the controller switches off the power and returns to stand-by mode.

SAFE TEMPERATURE:
If the safety temperature is exceeded, the controller switches to stand-by mode. Switching on again after returning to the maximum permissible temperature range must be done manually by pressing the I/0 button.